HOME / NEWS / DATACENTERS / EMERSON NETWORK POWER INTRODUCES ENERGY LOGIC 2.0 AND CASCADING SAVINGS CALCULATOR
Emerson Network Power Introduces Energy Logic 2.0 And Cascading Savings Calculator
With the inclusion of new technologies and best practices, Energy Logic 2.0 illustrates how the energy consumption of a 5,000 square-foot datacentre could be cut by up to 74 percent using available technologies. It accomplishes this by leveraging the cascade effect, the cornerstone of the Energy Logic approach.
The cascade effect quantifies how savings at the IT component level are magnified in the supporting systems, recommending an overall approach that focuses on optimising the efficiency of core IT systems to drive the greatest savings. In addition to the cascade effect, Emerson Network Power has quantified the “reverse” cascade effect: the total energy wasted by stranded capacity.
“Energy Logic 2.0 clearly shows there still are great opportunities to optimise the datacentre,” said Jack Pouchet, Vice President of Business Development and Director of Energy Initiatives, Emerson Network Power. “Energy efficiency remains a priority, and a new generation of management technologies that provide greater visibility and control of datacentre systems has arrived. The datacentre industry is better positioned than ever to make a serious impact in reducing overall datacentre energy consumption.”
Datacentre managers can use the Cascading Savings Calculator to explore the impact Energy Logic 2.0 strategies might have on their facility. Users enter their compute load and facility PUE, then adjust sliding scales for nine strategies to show percent utilisation. Based on this information, the calculator will approximate a strategy’s impact on compute load, PUE, and total energy and cost savings. The strategies datacentre managers can explore are Low-Power Components, High-Efficiency Power Supplies, Server Power Management, ICT Architecture, Virtualisation and Consolidation, Power Architecture, Temperature and Airflow Management, Variable Capacity Cooling and High-Density Cooling.
By trying out the Cascading Savings Calculator, datacentre managers can see how implementing each strategy – and varying degrees of each strategy – might impact their savings.
14th May, 2013 by Biztech2.com Staff
IBM To Help Indian Co-Operative Banks Enhance Customer Services
13th May, 2013 by Biztech2.com Staff
Brocade, EMC Deliver Software-Defined Storage For Fibre Channel SANs
7th May, 2013 by Biztech2.com Staff
![]()
MORE IN DATACENTERS
Brocade Unveils 'On-Demand Data Center' Strategy
17th May, 2013 by Biztech2.com Staff
The 'On-Demand Data Center' strategy from Brocade represents another...
IBM To Help Indian Co-Operative Banks Enhance Customer Services
14th May, 2013 by Biztech2.com Staff
IBM datacentre solution reduces energy use by 25 percent, while significantly...
SLAs Can Hold Back The Move To A Smarter DC
13th May, 2013 by Aletta D'cruz
Nick Knupffer APAC & PRC Marketing Director, DCSG, Intel explains how...
Brocade, EMC Deliver Software-Defined Storage For Fibre Channel SANs
13th May, 2013 by Biztech2.com Staff
This approach helps eliminate datacentre cost and complexity by improving...
Arista Enhances Its Modular Switching Platform
7th May, 2013 by Biztech2.com Staff
The Arista 7500E offers 1,152 10GbE, 288 40GbE, or 96 100GbE wire-speed ports,...

















There are no comments on this article yet. Why don't you post one?